Oil Heating To Steam Boilers

  • Sample Coolers for Boiler Water,/Feedwater/Condensate |USA

    Sample coolers. For the safe operation of steam boilers, the analysis of boiler water, boiler feedwater, and condensate is important. Accurate analysis of the feedwater and condensate require correct sampling methods and accurate instrumentation. Using GESTRA's sample coolers, a water sample can safely be taken from a steam boiler, steam Learn More

  • Water Sample Coolers - Sampling Water in Boiler Plants

    Water Sample Coolers - Sampling Water in Boiler PlantsLearn More

  • SC20 Sample Coolers - First for Steam Solutions

    Boiler Controls 318 SC20 Sample Coolers Description The Spirax Sarco SC20 sample cooler is used to cool samples of boiler water or steam. The cooler consists of a stainless steel coil, through which the sample flows, and a stainless steel body, through which cooling water flows in the opposite direction.Learn More

  • Sample Coolers - Complete Boiler Room Solutions

    Sample Coolers. The sample cooler is a low-pressure-drop system for monitoring boiler water quality without shutting down the boiler system. Heavy-duty, all stainless steel wetted parts. The design has baffling on the shell side to achieve high cooling-water flow, …Learn More

  • Sample Cooler - EWT Water Technology

    Jul 31, 2020 · Sample Cooler ← Home • Products • Sample Cooler ↓ Summary • Design Example • Applications • Technical Data • Downloads Summary: A sample cooler serves for safe sampling, cooling and if applicable condensation of hot fluids. The following descriptions are limited to water to water heat exchangers used in steam boiler plants and hot water boiler plants for the above purposes.Learn More

  • Boiler Venting Stainless Steel Venting IN STOCK For

    Open the cold-water inlet valve fully and ensure cooling water is flowing to drain. Open the sample-regulating valve slowly until system water starts to flow, then allow sample to run to waste for a suitable period to purge the stagnant water in the sample line. Regulate the …Learn More

  • GESTRA Sample Cooler - GESTRA Malaysia, SCHUBERT & …

    GESTRA Sample Cooler. GESTRA sample coolers are specially designed for taking samples of boiler water for analysis. They prevent steam flashing off from the sample which is both dangerous and results in an incorrect boiler water analysis. Sampling is of special importance for …Learn More

  • Spirax Sarco 4037195, SC20 Sample Cooler w/ Ferrule

    Item Features. For boiler water, steam, or condensate sampling. Stainless steel body and coil to minimize corrosion. Counter current flow for efficient cooling. Note: The SC20 sample cooler is not polished or specially treated internally, and the internal finish of the coil is not specified. 10 barg at 100 deg C maximum design pressure.Learn More

  • SC20 Sample Coolers - Spirax Sarco - PDF Catalogs

    The Spirax Sarco SC20 sample cooler is used to cool samples of boiler water or steam. The cooler consists of a stainless steel coil, through which the sample flows, and a stainless steel body, through which cooling water flows in the opposite direction. A pre-drilled mounting bracket is …Learn More

  • Sample Coolers - Thomasnet

    Manufacturer & distributor of boiler sample coolers. Available in carbon steel shell construction with 316 stainless steel coil, 1/4 in. NPT 316 stainless steel hot water fittings & 3/8 in. NPT steel cold water fittings. Boiler sample cooler shell can withstand pressures up to 250 psi & boiler sample cooler coil up to a pressure of 2,500 psi.Learn More

  • Boiler Sample Cooler - Ideal for Boiler and Steam Sampling

    Boiler Blowdown Cooler Model Number CW-ESC-SS is used as a safe method of obtaining a water sample from boilers, feedwater lines, and steam lines. The specifications are as follows: Stainless Steel Shell; Stainless Steel End Caps; 1/4" NPT Stainless Steel Adaptors; Continuous 316 Stainless Steel Coil; Coil rated to 2,500 psi; Shall Rated to 250 psiLearn More

  • Sample Coolers for Steam & Condensate | GESTRA

    Sample coolers. For the safe operation of steam boilers the analysis of boiler water, boiler feedwater and condensate is important. Accurate analysis of the feedwater and condensate require correct sampling methods and accurate instrumentation. Using …Learn More

  • Sample Coolers | US | Spirax Sarco

    Stainless steel sampler coolers. Take boiler water samples safely. Suppresses flash steam ensuring an accurate sample. SC20 Sample Cooler SC20 Sample Cooler …Learn More

  • An Introduction to Water Sampling and Testing of Water …

    Boiler water sample coolers are critical for analyzing and treating boiler water to prevent scale buildup and corrosion. The standard tubing design pressure for the sample side is 2000 PSIG. The standard external shell design is 285 PSIG (except for the Type 530 cooler). Higher pressure designs are available.Learn More

  • Water Sample Coolers - Sampling Water in Boiler Plants

    Sample coolers should be installed whenever it is necessary to obtain a sample of water from a system where the operating temperature exceeds 60° C, ie steam boilers, steam and condensate mains, closed heating circuits, and water systems.Learn More

  • Steam and water sampling: Poorly obtained samples may …

    carried out to fully condense any flash steam. The sample cooler reduces boiler water temperature to around 25°C ready for immediate analysis. SCS20 (sample cooler system) To facilitate purchasing and installation Spirax Sarco supply a packed sample cooler system (SCS20) . This includes:-• SC20 sample cooler (BSP only). • Cooling water inlet valve ½" BSP. • Sample inlet valve ¼" BSP. • Two compression …Learn More

  • Spirax Sarco 4037195, SC20 Sample Cooler w/ Ferrule

    Item Features. For boiler water, steam, or condensate sampling. Stainless steel body and coil to minimize corrosion. Counter current flow for efficient cooling. Note: The SC20 sample cooler is not polished or specially treated internally, and the internal finish of the coil is not specified. 10 barg at 100 deg C maximum design pressure.Learn More

  • COCHRANE Sample Cooler Tech Datasheet Sep2017

    Sample Cooler One-Piece, All-Stainless Steel Cooler That Provides Ef˜ cient and Reliable Sampling at a Low-Cost It is designed for safe sampling of hot water or steam at pressures up to 3500 psig ensuring reliable and consistent sampling. In addition to the prime application of cooling samples of boiler water and feed water that play a Learn More

  • STEAM SAMPLING SYSTEMS - WATER SAMPLING - …

    Sample Coolers - steam, boiler water, hot liquids Learn More

  • Sample Coolers, Sample Cooler, Manufacturer, Supplier

    Sample cooler for safe and accurate boiler water and chemical material sampling. Eliminets flashing off from the sample & false water analysis. Prevents danger of scalling. Compact coil layout. Counterflow design for efficient cooling. Fixed or removable coils of copper or stainless steel. Complete with compression fittings for sample connections.Learn More